Regarding performance indicators of fireproof and thermal insulation materials, absolute values are often used as statistical indicators. Still, such fundamental values are not convenient for judging the performance of products. Therefore, fire protection standards in various countries have emerged as the times require.

fire protection standards

Through these standards, we can easily have a basic understanding of material properties. Let's look at Heaterk to understand the fire test standards of fire insulation materials in various countries.

1. China's fire test standards for building materials products

 

GB 12955—2015 Fire doors

GB 12441-2018 Decorative fire retardant coating

GB 14907-2018 Fire-retardant coatings for steel structures

GB 14102-2005 Fire shutter

GB 23864-2009 Fireproof sealing material

GB 15763.1-2009 Safety glass for construction - Part 1: Fireproof glass

GB/T 16809-2008 Steel fire windows

GA 304-2012 Plastic Pipe Firestop

2. China's fire test standards for building materials

GB 8624-2012 Classification of combustion performance of building materials and products

GB 20286-2006 Requirements and marking of flame retardant products and components in public places

GB/T 2408-2008 Test method for plastic combustion performance-horizontal and vertical combustion method

GB/T 8323.2-2008 Test method for combustion performance of plastics Test method for smoke density

GB T 7633-2008 Fire resistance test method for doors and shutters Standard

GBT 9978.1-2008 Test method for fire resistance of building components - Part 1 General requirements

GB/T 9978.4-2008 Test method for fire resistance of building elements - Part 4: Special conditions for load-bearing vertical partition elements

GB T 9978.5-2008 Test method for fire resistance of building components - Part 5: Special needs for load-bearing horizontal partition construction

GB T 9978.6-2008 Test method for fire resistance of building components - Part 6: Particular requirements for beams

GB T 9978.7-2008 Test method for fire resistance of building components - Part 7: Particular requirements for columns

GB T 9978.8-2008 Test methods for fire resistance of building elements - Part 8: Particular requirements for non-load-bearing vertical partition elements

GB T 9978.9-2008 Fire resistance test method for building components - Part 9: Special conditions for non-load-bearing ceiling components

GBT 5454-1997 Textile combustion performance test-oxygen index method

GB/T 5455-2014 Textiles - Combustion properties - Vertical direction - Determination of damage length smoldering and afterburning time

GB/T 5464-2010 Test method for non-combustibility of building materials

GB/T 7633-2008 Fire resistance test method for doors and shutters

GB/T 8333-2008 Test method for flammability of rigid foam plastics Vertical flammability

GB/T 8332-2008 Test method for combustion performance of foamed plastics Horizontal combustion method

GB/T 8625-2005 Test method for flame retardancy of building materials

GB/T 8626-2007 Test method for flammability of building materials

GB/T 8627-2007 Test method for smoke density of building materials

GB/T 11785-2005 Determination of Critical Radiation Flux of Flooring Materials - Radiant Heat Source Method

GB/T 14402-2007 Combustion performance of building materials and products-Test of calorific value of combustion

GB/T 20284-2006 Single Combustion Test of Building Materials or Products

GB/T 20285-2006 Material Smoke Toxicity Hazard Classification

GB 50222-2001 Technical code for fire protection of interior decoration of buildings

GB/T 11020-2005 List of methods for combustion characteristics of solid non-metallic materials exposed to flame sources

GB/T 11785-2005 Determination of Critical Radiation Flux of Flooring Materials Radiant Heat Source Method

GB/T 16172-2007 Test method for the heat release rate of building materials

GB/T 24573-2009 Test method for fire resistance of vault and archive doors

GB/T 12513-2006 Test method for fire resistance of glass-inlaid components

3. International fire test standards for building materials

ISO 834-1 - Fire resistance tests - Building elements - Part 1 General requirements

ISO5659-2 Optical Density Determination of Single Smoke Box

ISO11925-2 single ignition source flammability test

ISO1182 non-combustibility test of building materials

ISO 1716 Determination of Heat of Combustion

ISO9239-1 Flooring Materials - Radiant Heat Source Method

ISO5660-1 Heat Release Rate Test

ISO 5660-2 Burning tests - Heat release, smoke generation, and mass loss - Part 2 Dynamic determination of smoke

ISO 5658-2 Fire test for the lateral flame spread of building elements (international standard)

4. American fire test standards for building materials

ASTM E1354 Oxygen Consumption Method for Determination of Heat Release and Smoke Release Rates from Materials

ASTM E 970 Test Method for Critical Radiant Flux of Attic Floor Insulation Using Radiant Heat Energy Exposure

ASTM D3675 Test Method for Surface Burning of Flexible Porous Materials by Radiant Heat Source Method

ASTM E814 Test Method for Ignition Temperature of Penetration Fire Arresting Systems

ASTM E84 Surface Burning Properties of Building Materials

ASTM E119 Fire Testing of Building Materials

ASTM E136 Nonflammability Test

ASTM E162 Radiant Heat Source Surface Burning Performance Test

ASTM D3675 Fire Test for Surface Burning of Flexible Porous Materials with Radiant Heat Sources

ASTM E648 Critical Radiation Test for Floor Materials

ASTM D2843 Plastic Smoke Density Test

NFPA259 Building Materials Potential Heat Test

UL 723 Method for Determination of Surface Burning Properties of Building Materials

UL 263 Fire Testing of Building Structures and Materials

UL 10C Fire Tests for Fire Door Fittings

UL 10B Fire Test for Fire Door Fittings

UL 2043 Air Handling Separation Products and Their Accessories Fire Tests for Heat and Visible Smoke Release

5. EU fire test standards for building materials

EN13823 Single-body combustion test of building materials

EN 1363 Flame Resistance Test

EN 1364 Non-load bearing flame test

EN 1365 Load bearing flame resistance test

EN 13501-1 Determination of fire rating of building products

EN 13501-2-2007 Classification of fire resistance of building products and components in the European Union

EN 1634-1 Fire resistance testing of building materials - Part 1: Fire-rated doors and shutters

6. Canadian fire test standards for building materials

CAN/ULC-S127 Determination of flammability characteristics of non-melting foamed plastic building materials by the corner method

CAN/ULC-S114-05 Test method for non-combustibility of building materials

CAN/ULC-S102-10 Test Method for Surface Burning Characteristics of Building Materials and Fittings

CAN/ULC-S102-3 Method of Fire Test for Diffusers and Lenses of Luminaires

CAN/ULC-S102-2 Test method for building surface burning characteristics of floors, floor coverings, and other materials and accessories

CAN/ULC-S129 Insulation Resistance Smoldering Test Method

CANNULA-S135 Test Method for Determining Combustion Properties of Building Materials Using an Oxygen Consumption Calorimeter

7. Australian fire test standards for building materials

AS1530 Flame Retardant Fire Test of Building Materials

AS1530.4 Fire resistance test of building materials

AS/NZS 1530.2 Fire testing of building materials, elements, and members, part 2 Materials flammability testing

AS/NZS 1530.1 Fire testing of building materials, components, and members, Part 1 Material flammability testing

AS 1530.3 Building materials testing for flammability, flame spread, and heat release smoke performance

AS/NZS 3837 Oxygen Consumption Calorimeter Test Method for Heat Release and Smoke Generation of Materials and Products

8. British fire test standards for building materials

BS 5839-1 Building fire detection and alarm systems - Part 1: System design, installation, commissioning, and maintenance

BS 5803-3 Insulation of pitched roof spaces of dwellings - Specification for blown cellulose fiber insulation

BS 5803-2 Insulation of pitched roof spaces of dwellings - Part 2 Shot or granular artificial minerals applied by blowing

BS 476-3 Fire testing of building materials and components - Fire testing of exposed parts of roofs

BS 476-4 Non-combustibility testing of building materials

BS 476-5 Fire test for fire resistance of building materials and components - ignitability test

BS 476-6 Fire tests for fire resistance of building materials Fire tests on building materials and structures - Part 6: Test methods for the spread of flames in products

BS 476-7 Fire testing of building materials and systems - Part 7: Test methods for the determination of flame surface extension levels for products

BS 476-11 Method for determining thermal radiation of building materials

BS 476-15 Fire testing of building materials and structures - Test method for the heat release rate of products

BS 476-20 Fire resistance test for building materials

BS 476-21 Fire resistance testing of load-bearing materials

BS 476-22 Fire resistance test of non-load bearing parts of building materials

BS 476-23 Fire testing of building materials and components - Test method for the contribution of members to the fire resistance of components

BS 7955 Control nets and sheets for construction work - Specification for properties and test methods

ENV 1187 Fire Testing of Building Materials and Components - Fire Testing of Exposed Roofs

9. French fire test standards for building materials

NF P92-501 Building Materials Class M Fire Test

NF P92-503 Building Materials Class M Fire Test

NF P92-504 Combustion Flame Propagation Rate Test

NF P92-505 Burning Droplet Test

NF P92-507 M Grade Grading Standard

10. German fire test standards for building materials

DIN 4102-1 Fire performance class test for building materials

If you are looking for high-quality fire insulation materials in China, why not contact the experts at Heaterk? With 22 years of experience, we are familiar with and understand the different fire protection standards of other countries, and now get the professional team of Heaterk!

Related News
Read More >>
How Does The Thickness Of Insulation Fabrics Affect Heat Loss? How Does The Thickness Of Insulation Fabrics Affect Heat Loss?
Dec .05.2024
Discover how insulation fabric thickness impacts heat loss and explore professional strategies to optimize thermal management and energy efficiency.
Fire-Fighting Fabrics: Insulation Blanket That Prioritize Safety! Fire-Fighting Fabrics: Insulation Blanket That Prioritize Safety!
Jul .10.2024
Introducing groundbreaking fire-fighting fabrics, meticulously designed to provide unparalleled safety. Insulation blankets are your shield against the dangers of fire and heat, ensuring your protection in the face of emergencies.
Fire Pit Mat: The Key to Enjoying Outdoor Fires Without Risk! Fire Pit Mat: The Key to Enjoying Outdoor Fires Without Risk!
Jun .25.2024
Discover the importance of fire pit mats in safeguarding your outdoor spaces from heat and sparks, ensuring your gatherings are safe and stylish. Choose the right mat for your deck, patio, or grass area.
High Temperature Insulation: The Role of a High-Silica Fabric High Temperature Insulation: The Role of a High-Silica Fabric
Jun .14.2024
Let's examine the utilization of high-silica fabric for high-temperature insulation, understand its properties, performance, and applications in various industries.